Jura Error Codes
Jura Error GIGA 12: Left Grinder Failed to Activate - GENERATION 2 Models - The HALL Sensor on Right Grinder Failed
The following may be the cause of the problem:
The left grinder failed to activate. The motor has seized or cannot activate due to the burrs being impeded by a foreign object, most often a stone.
Visually inspect the grinder for blockages and foreign objects. If the grinder is clear, the grinder may need to be replaced.
The HALL sensor on the right grinder failed to send the correct impulses to activate the grinder.
Replace the right HALL sensor on the grinder.
The Power Board is defective. The board is failing to receive the necessary signal to activate the grinder.
Replace the PCB; however, sometimes it is more economical to buy a new or refurbished machine.
Possible Faulty Parts:
Fix:

Repair Services
Want us to baby your baby?
Your Jura coffee machine was built to last; however, it will need a tune-up from time-to-time. Even a Porsche has a limited number of miles it can drive before the oil needs to be changed. We offer a comprehensive repair/refurbishing service to get your coffee machine operating at its peak capacity, again.
​